Porcelain and mosaic tiles for commercial steam rooms, selected for low water absorption, thermal shock resistance and barefoot slip performance on floors and seating. Suitable for spa, hotel, gym and leisure facilities. Every range on this page includes options that can be specified for steam room environments. Grip and structured finishes in ranges such as Truman, Maslic, Jacuro and Buk are suited to floors and bench tops. Polished and smoother finishes such as Delano are best kept to walls and ceilings, where they shed condensation and wipe clean quickly. Mosaics like Victorian Mosaic follow the curves of benches and vaulted ceilings. Suitable for spa, hotel, gym and leisure facilities.

/ Collection

Steam Room Tiles

Filters

Dawson MixDawson Mix - Alternative view
11 Sizes9 Colours2 Finishes
Dawson MineralDawson Mineral - Alternative view
15 Sizes25 Colours2 Finishes
BukBuk - Alternative view
9 Sizes10 Colours3 Finishes
TrumanTruman - Alternative view
14 Sizes3 Colours2 Finishes
MaslicMaslic - Alternative view
6 Sizes30 Colours2 Finishes
ElementiElementi - Alternative view
6 Sizes4 Colours1 Finish
JacuroJacuro - Alternative view
10 Sizes3 Colours3 Finishes
DelanoDelano - Alternative view
8 Sizes8 Colours1 Finish
Victorian MosaicVictorian Mosaic - Alternative view
3 Sizes5 Colours1 Finish
KnightonKnighton - Alternative view
7 Sizes16 Colours1 Finish

A steam room runs at 40 to 50°C and close to 100% relative humidity for hours at a time, then cools between sessions. Every surface, floor, wall and bench, is continuously wet, heated and cycled, so the tile, adhesive, grout and the build-up behind them all have to be specified as one system.

Specifying steam room surfaces

  • Water absorption. Specify group BIa porcelain at 0.5% absorption or less to ISO 10545-3. Saturated vapour finds any porosity in the tile body, and porous materials take on moisture, stain and lose bond over time.
  • Thermal shock resistance. Heating and cooling cycles stress the tile and the bond line. Confirm thermal shock resistance to ISO 10545-9, and use a deformable C2 S1 adhesive to BS EN 12004 rated for wet and heated conditions.
  • Barefoot slip resistance. Floors and bench tops are used barefoot and permanently wet. Specify DIN 51097 class B as a minimum, class C on sloped areas, with a wet PTV of 36 or above to BS 7976-2.
  • Vapour control behind the tile. Steam drives into the substrate rather than running off it. A vapour tight tanking membrane over a cement or XPS backer board is essential, and gypsum based boards should not be used anywhere in the enclosure.
  • Mosaics for benches and curves. Seating, coves and curved walls are usually formed in mosaic, which follows the profile without cutting and gives more grout lines for grip on a wet seat.
  • Grout and movement joints. Use epoxy grout to BS EN 13888 throughout, and detail movement joints at perimeters and changes of plane to BS 5385 to accommodate thermal movement.

Steam rooms are normally specified as part of a wider wet leisure scheme. See spa tiles for treatment and changing areas, swimming pool tiles for immersed applications and mosaic tiles for the full mosaic range.

Steam room tiles by surface: floors, walls, benches and ceilings

Each surface in a steam room takes a different load. Specifying steam room tiles zone by zone, rather than as one finish across the whole enclosure, is what keeps the room watertight and easy to clean over its service life.

Ceilings: Condensation forms continuously on the ceiling. If the ceiling is flat, it collects and drips onto bathers. Steam room ceilings are usually formed with a pitch or a barrel vault so condensate runs to the walls and down to the floor drain. Mosaic is the practical choice on a vault because small modules follow the curve without lipping. Large format tiles suit a straight pitch where cuts can be kept to the perimeter. Ceiling tiles need full bed adhesive coverage, because any voids hold moisture overhead.

Walls: Walls carry the heaviest condensation load after the ceiling. Glazed or polished faces shed water more readily than textured ones, and they make the routine wipe down after each session quicker. Where the steam outlet sits low on a wall, the tiles around it take the highest local temperatures in the room. Detail that area with the same adhesive and grout system as the rest of the enclosure, never as a patch repair.

Benches: Seating is normally built from tileable seating profiles or formers, often with integral heating, and finished in mosaic so the tiles can follow the front radius and any curved backrest. The seat should fall slightly towards the front edge so water drains off rather than pooling under bathers. Bench tops are a seated contact surface, so a matt or lightly textured finish is more comfortable and less slippery than a high gloss.

Floors: Floors take barefoot traffic and all the water that runs off the walls and ceiling. They need consistent falls to a linear or point drain and a tile format that can follow those falls without stepped edges. Smaller formats and mosaics make the falls easier to achieve. Coved skirting tiles at the wall junction remove the internal corner where water and residue collect.

Trims and fittings: Where trims are used at bench edges, external corners or the door threshold, specify grade 316 stainless steel or a non-metallic profile. Standard trims can corrode in a constantly hot and saturated atmosphere.

Steam room tiles FAQs

What tiles are suitable for a steam room?

Fully vitrified porcelain with water absorption of 0.5% or less, verified thermal shock resistance and a barefoot slip rating for floors and seating. Porcelain mosaics are the standard choice for benches and curved surfaces. Natural stone and standard ceramic wall tiles are generally avoided because of their porosity.

Can large format tiles be used in a steam room?

On flat walls, yes, provided the substrate is flat, fully tanked and the adhesive bed is solid with no voids. Floors need a fall to the drain, so they are usually laid in smaller formats or mosaic that take up the fall without lipping.

What grout should be used in a steam room?

Epoxy grout. Cementitious grout absorbs moisture under constant vapour, harbours bacteria and breaks down under the cleaning regime a commercial steam room needs.